menu

Home Analog Control Panel (up to 8 Loop) Legacy Series

Analog Control Panel (up to 8 Loop) Legacy Series

    • 8 x Loops (242) capacity (1936) addressable points
    • Max 10 Loops Standalone
    • Comply with EN54 and UL864
    • Modular constructed for future expansion
    • 40 x15 lines Colour Graphical LCD Display
    • Up to 999 programmable zones and 140 Zone indication
    • Networked with all SHIELD Intelligent Fire panels up to 64 Nodes, Optional Fiber Optic and LAN Network Interface.
    • RS 485 mimic and repeater output up 64
    • RS 232-USB CRT interface, including P-CGS graphic
    • History record-999 fire incident only and 999 event capacity in non-volatile memory
    • Online/Offline Programmable form PC
    • Walk Test Function with optional silent mode
    • Fully simulation of Cause and Effect
    • Advanced user friendly programming software including ‘Fuzzy Logic’.
    • Built in Fire Alarm, FPE, Fault and Alarm Router output
    • Auto Programming Day and Night Mode
    • Enable and Disable function
    • Pre-Alarm and Acknowledge Function
    • Duplicate address checking
    • Device mismatch
    • Dirty Detector Reporting
    • Panel Printer included
    • Built in Battery charger
Standard EN54 Part 2/4; BS5839 part 4
Approvals LPCB, CE
Main Input Voltage 220 ± 10% VAC 50/60 Hz (PSU)
Input Current Rating 1 A
System Operating Voltage 24 VDC Nominal (20-27 VDC)
Loop Capacity 1-10:242- Address per loop
Zone Capacity 999 zones programmable
Operating Temperature 0°C to +40°C at 95% relative humidity
24 VDC Fused Relay Output Maximum Load 500mA at 17-28 VDC
Zone Capacity 30 Zones Programmable
Standby Batteries Twin 12Volt Battery (PSU)
Sounder Circuits(3) Fire Alarm Output: 200mA/24Vdc/4.7Ω EOLR
F.P.E. Output: 500mA/24Vdc/4.7Ω EOLR
Sounder Circuit Output: 1A/24Vdc/4.7Ω EOLR
Fuses Mains 1A (20mm A/S ceramic),
Sounders (2): 1A (20mm A/S),
Fire alarm Output 0.5A (20mm A/S),
Battery: 2A (20mm A/S HRC ceramic)
Common Fault Relay Output Volt-Free changeover (NO/NC) 1.0A at 24 VDC
Battery Charging Current Limit 600mA
Event Capacity 999 events plus 999 fire event only
Protection Rating IP 42
Dimension (HxLxW) Outer: 850x484x185 mm,
Inner: 804x440x150 mm

Do you want to contact with us?

If you want to contact with us? please fill free an message by contact page.

Request a free consultation

 

8 years Experiences in  my business service

 

Send us an email and we will get in tuch shortly or phone between 9.00am to 6.00pm  Saturday to Thursday .