Rated Capacity (US GPM) Rated Pressure Range (PSI)
50 50 – 139
SL.
No.
Pump Model UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated
Speed
(RPM)
Suction Inlet
Dia. (Inch)
Discharge
Outlet
Dia. (Inch)
Stage(s)
1 NF-E 32-20 50-87 2900 2 1.25 1
2 NF-E 32-26 88-139 2900 2 1.25 1
3 NF-E 40-20 59-95 2900 2.5 1.5 1
4 NF-E 40-26 77-128 2900 2.5 1.5 1
5 NF-E 50-20 58-89 2900 2.5 2 1
6 NF-E 50-26 93-138 2900 2.5 2 1
7 NF-E 65-20 58-89 2900 3 2.5 1
8 NF-ES 32-20 72-128 72-126 3550 2 1.25 1
100 53 – 139

 

SL.
No.
Pump Model UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated
Speed
(RPM)
Suction Inlet
Dia. (Inch)
Discharge
Outlet
Dia. (Inch)
Stage(s)
1 NF-E 32-26 126 2900 2 1.25 1
2 NF-E 40-20 53-92 2900 2.5 1.5 1
3 NF-E 40-26 70-124 2900 2.5 1.5 1
4 NF-E 50-20 61-91 2900 2.5 2 1
5 NF-E 50-26 93-139 2900 2.5 2 1
6 NF-E 65-20 58-88 2900 3 2.5 1
7 NF-ES 32-20 62-119 3550 2 1.25 1
8 NF-ES 40-26 66-136 67-135 3550 2.5 1.5 1
150 56 – 139
SL.
No.
Pump Model UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated
Speed
(RPM)
Suction Inlet
Dia. (Inch)
Discharge
Outlet
Dia. (Inch)
Stage(s)
1 NF-E 40-26 114 2900 2.5 1.5 1
2 NF-E 50-20 62-93 2900 2.5 2 1
3 NF-E 50-26 90-139 2900 2.5 2 1
4 NF-E 65-20 56-86 2900 3 2.5 1
5 NF-ES 40-26 60-131 60-129 3550 2.5 1.5 1
200 84 – 216

 

SL.
No.
Pump Model UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated
Speed
(RPM)
Suction Inlet
Dia. (Inch)
Discharge
Outlet
Dia. (Inch)
Stage(s)
1 NF-E 65-26 92-141 94-144 2900 3 2.5 1
2 NF-E 65-32 133-211 135-216 2900 3 2.5 1
3 NF-ES 65-26 84-161 3 2.5 1
250 89 – 211
SL.
No.
Pump Model UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated
Speed
(RPM)
Suction Inlet
Dia. (Inch)
Discharge
Outlet
Dia. (Inch)
Stage(s)
1 NF-E 65-26 89-140 91-143 2900 3 2.5 1
2 NF-E 65-32 132-210 133-211 2900 3 2.5 1
3 NF-E 80-32 126-208 2900 4 3 1
300 75 – 213

 

SL.
No.
Pump Model UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated
Speed
(RPM)
Suction Inlet
Dia. (Inch)
Discharge
Outlet
Dia. (Inch)
Stage(s)
1 NF-E 65-26 87-139 88-142 2900 3 2.5 1
2 NF-E 65-32 129-209 130-206 2900 3 2.5 1
3 NF-E 80-26 87-135 93-145 2900 4 3 1
4 NF-E 80-32 125-207 132-213 2900 4 3 1
5 NF-ES 65-26 75-160 77-158 3550 3 2.5 1
6 NF-ES 80-26 80-138 3550 4 3 1
7 NF-ES 80-32 151-212 3550 4 3 1
350 91 – 211
SL.
No.
Pump Model UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated
Speed
(RPM)
Suction Inlet
Dia. (Inch)
Discharge
Outlet
Dia. (Inch)
Stage(s)
1 NF-E 80-26 91-144 2900 4 3 1
2 NF-E 80-32 131-211 2900 4 3 1
400 76 – 210

 

SL.
No.
Pump Model UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated
Speed
(RPM)
Suction Inlet
Dia. (Inch)
Discharge
Outlet
Dia. (Inch)
Stage(s)
1 NF-E 80-26 84-133 88-142 2900 4 3 1
2 NF-E 80-32 122-204 130-209 2900 4 3 1
3 NF-ES 80-26 76-137 79-138 3550 4 3 1
4 NF-ES 80-32 147-207 148-210 3550 4 3 1
450 75 – 207
SL.
No.
Pump Model UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated
Speed
(RPM)
Suction Inlet
Dia. (Inch)
Discharge
Outlet
Dia. (Inch)
Stage(s)
1 NF-E 80-26 81-132 83-141 2900 4 3 1
2 NF-E 80-32 119-203 129-207 2900 4 3 1
3 NF-ES 80-26 75-134 78-137 3550 4 3 1
4 NF-ES 80-32 145-205 145-207 3550 4 3 1
500 79 – 204

 

SL.
No.
Pump Model UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated
Speed
(RPM)
Suction Inlet
Dia. (Inch)
Discharge
Outlet
Dia. (Inch)
Stage(s)
1 NF-E 80-26 130 79-139 2900 4 3 1
2 NF-E 80-32 202 126-203 2900 4 3 1
3 NF-ES 80-32 142-204 140-204 3550 4 3 1

 

 

 

 

 